HARBEN
ˈPˈ TYPE PUMP
SERVICE MANUAL
Part No. 061-352
Flowplant Group Ltd
Issue 9 - November 2022
This manual contains
IMPORTANT Safety Information
Flowplant P Pump Manual Issue 9
ii
Flowplant Group Ltd.
Gemini House
Brunel Road
Churchfields Ind. Est.
Salisbury
Wiltshire, SP2 7PU
England
t:+44 (0)1722 325 424
f:+44 (0)1722 411 329
Harben Inc.
P.O.Box 2250
Cumming
GA 30028
USA.
t:+1 770 889 9535
f:+1 770 887 9411
Flowplant P Pump Manual Issue 9
1
HARBEN
ˈPˈ TYPE PUMP SERVICE MANUAL
CONTENTS
FOREWORD
IMPORTANT SAFETY INFORMATION
SECTION 1 PUMP TECHNICAL DATA
SECTION 2 PUMP INSTALLATION
SECTION 3 GENERAL OPERATING INFORMATION
SECTION 4 PUMP MAINTENANCE AND OVERHAUL PROCEDURES
SECTION 5 WARRANTY
A detailed contents list precedes each section
Flowplant P Pump Manual Issue 9
2
FOREWORD`
This manual is primarily concerned with the Harben 'P' Type Pump. Details are also given of the similarly
constructed High Lift Pump, in addition, general safety and operating information for the equipment
using the pumps is also included.
The conversion of pressurised water into a high velocity jet and its use as a cleaning and cutting tool is
now familiar to, and used by, many people in a wide range of industries.
High pressure water can achieve remarkable results without the use of heat or chemicals and cost
savings over conventional maintenance methods can in many cases show that a water jetting unit will
pay for itself in hours rather than years.
Many companies have problems for which high pressure water offers a rapid solution, yet hesitate to
consider this method because of the generally accepted high cost of such equipment. Backed by many
years of design and manufacturing experience, Harben pumps are setting new standards of performance
and reliability. The capital and operating costs are such that these offer an attractive return on
investment that really makes sense.
Flowplant Group Ltd have a policy of continual research and improvement and reserve the right to make
such modifications and design changes as are considered necessary in the light of experience, however,
this copy of the manual will not be amended.
No part of this manual may be reproduced or copied in any manner without written permission from
Flowplant Group Ltd.
Flowplant P Pump Manual Issue 9
3
HEALTH AND SAFETY AT WORK
There are two main categories of risk. These are:
a) Injury from impact of water
b) Injury from environment
All persons involved in water jetting should be made aware of the risks.
INJURY FROM IMPACT OF WATER
In the event that a person is injured by the impact of a water jet, the injury caused may appear
insignificant and give little indication of the extent of the injury beneath the skin and the damage to
deeper tissues. Large quantities of water may have punctured the skin, flesh and organs through a very
small hole that may not even bleed.
Immediate hospital attention is required and medical staff must be informed of the cause of the injury.
To ensure that this is not overlooked, all operators engaged on jetting should carry an immediately
accessible waterproof card which outlines the possible nature of the injury and bears the following text
which has been endorsed by the Employment Medical Advisory Service (EMAS) of the Health and Safety
Executive:
THIS MAN HAS BEEN INVOLVED WITH HIGH PRESSURE WATER JETTING AT PRESSURE UP TO 36750
LB/IN
2
(250 MPA, 2500 BAR, 2548 KG/CM
2
) WITH A JET VELOCITY OF 1536 MILES (2458 KM) PER HOUR.
Please take this into account when making your diagnosis. Unusual infections with micro-aerophilic
organisms occurring at lower temperatures have been reported. These may have gram negative
pathogens such as are found in sewage. Bacterial swabs and blood cultures may therefore be helpful.
A letter containing this and other relevant information should be sent to the doctor of each operator.
Where surgical examination is not immediately possible in remote situations, first aid measures should
be confined to dressing the wound and observing the patient closely until a medical examination has
been arranged.
If any person, object or article is accidentally struck by the jet, this fact must be reported to the
occupier's representative.
Flowplant P Pump Manual Issue 9
4
INJURY FROM ENVIRONMENT
Work should only be carried out if it is safe to do so. A thorough examination of the site should be
carried out before work is started. Refer to the Warnings and Cautions.
Special care should be taken where there is a danger of infection; there are many situations where
infection can take place. As a guide to avoiding infection, the following points should be considered:
a) Full protective clothing must be worn.
b) Always clean scratches or cuts immediately. Disinfect and cover with a strip of gauze and
impermeable plaster. SEEK MEDICAL HELP
c) Avoid rubbing eyes, nose or mouth with hands during working.
d) All contaminated clothing, vehicles and equipment should be thoroughly cleaned.
e) Operators should wash thoroughly after work and before eating, drinking or smoking.
Flowplant P Pump Manual Issue 9
5
SAFETY CODE OF PRACTICE
Full details of the Safety Code of Practice, when working with equipment containing a Harben pump, are
given in Section 3 of this manual. The basic rules of this code are as follows:
1. ALWAYS WEAR THE CORRECT PROTECTIVE CLOTHING.
2. ALWAYS ENSURE ALL EQUIPMENT IS IN A FIRST CLASS CONDITION.
3. NEVER WORK FROM A LADDER.
4. NEVER USE THE GUN WITH THE TRIGGER LOCKED ON.
5. NEVER POINT THE GUN AT ANYONE, EVEN IF SWITCHED OFF.
Only a responsible person who has received instruction in the operation of high pressure water jetting
equipment should be allowed to operate the equipment.
Flowplant P Pump Manual Issue 9
6
POTENTIAL HAZARDS AND MISUSE OF HIGH PRESSURE EQUIPMENT
Never use a jetter that isn’t regularly serviced according
to the manufacturer’s recommendations.
When a jetter is used to clean drains & sewers that are
contaminated with a hazardous substance it is possible
these may be entrained in the resulting aerosol and
inhaled by operators. Consider using respiratory
protection.
Do not spray flammable liquids - there is
a risk of explosion.
Ensure the correct fuel is used on all
occasions or there is a risk of explosion.
Never start the jetter when frozen. Operating a jetter
whilst frozen could cause high speed ice bullets to be
ejected from the jetter hose on machine start up.
Never start jetting a drain, sewer or pipe unless the jet
nozzle is safely inside the drain and pointing in the
direction that you intend it to travel.
When drain jetting a drain, sewer or pipe with an inside
diameter that is not small enough to prevent the hose
from turning back on itself, a drain jet extension (a piece
of straight rigid tube equivalent to the pipe diameter)
should be fitted between the end of the hose and the
nozzle.
Always use a safety leader hose at the beginning of the
main jetting hose to alert operators when the jet nozzle
is nearing the manhole entrance.
Always consider the use of a tiger tail hose feed guide to
protect the jetting hose from abrasion and prevent
premature failure.
Be aware that high pressure hoses can generate static
electricity which may need to be controlled when
working in hazardous areas.
Never direct a high pressure water jet
at electric power lines or electrical
equipment as serious injury or death
from electrocution could occur.
When jetting drains or sewers if there is a danger to
the general public from hoses laying across public
walkways they must be covered in such a way as to
protect against injury from hose failure and tripping
hazards.
Before starting work, check and ensure the drain
jets have no blocked holes or nozzles as this may
cause the pumping system to over pressurise which
could result in burst disc failure or bursting the
jetting hose.
Never attempt to unblock a fully choked drain or
pipe before considering the consequence of
releasing the blockage and having a plan to deal
with it. E.g. flooding, material ejection, drain nozzle
ejection.
Never attempt to clean drains or pipes in one pass
because this could lead to debris build up behind
the jet nozzle causing a pressure build up in the
drainage system. Be aware that a pressure build up
in the drain or pipe could cause the jet nozzle to be
ejected at speed back towards the operator.
Never enter the manhole to either place the jet
nozzle into or extract it from the drain entrance
unless the required confined space regulations have
been met.
Never work in a manhole with a radio remote
control transmitter that is not classified for use in
such areas.
Failure to follow the instructions where this icon
is shown can result in serious injury or even death
Flowplant P Pump Manual Issue 9
7
POTENTIAL HAZARDS AND MISUSE OF HIGH PRESSURE EQUIPMENT CONT’D
Failure to follow the instructions where this icon
is shown can result in serious injury or even death
Never use the hydraulic hose reel facility as a winch to
retract a jetting hose that has become stuck in the drain
or pipe. Damage to the hose could be caused that will
make subsequent hose failure more likely.
Never allow jetting hoses to become kinked and
always remove from service any jetting hose with an
outer cover that has worn through to the reinforcing
braid.
Never use the high pressure jetting hose for any
purpose other than sewer, drain or pipe cleaning,
e.g. winching vehicles or other plant.
Never use jetting nozzles and/or accessories that have
not been calibrated for the jetting machine pump
performance as this could cause rapid over
pressurisation catching operators unaware.
Never attempt to clean a drain or pipe with a
nozzle that has more forward force than rear force. It
could be ejected back toward the operator
causing injury.
Never attempt to clean a drain or pipe with a chain flail
type jet that has unequal chain lengths as this could lead
to severe vibration and high pressure hose failure.
When using a venturi jet pump to remove fluid from a
flooded manhole never place your fingers into the pump
inlet as they could be trapped by the
vacuum and cause injury.
When using a venturi jet pump to remove fluid from a
flooded manhole always secure the free end of the pump
hose securely and ensure adequate drainage is in place
to deal with high volumes of pumped water.
Never use a dry shut type foot control valve on a jetter
that does not have a pressure unloader valve as this
could result in burst disc failure or bursting the jetting
hose.
Never use a dry shut type jetting gun valve on a jetter
that does not have a pressure unloader valve as this
could result in burst disc failure or bursting the jetting
hose.
When using a dry shut type system be aware that
high pressure can be retained in the jetting hose
even after the machine has been shut down.
Always discharge pressure in a safe manner after
machine shut down.
When working with a gun always consider using a
safety shroud to provide the operator with greater
protection in the event of a hose burst.
Never point the gun at anyone as injury from high
pressure water will occur if the jet stream comes
into contact with body parts.
Never work on a slippery surface because the
reaction force of the jetting gun could cause you to
become unstable and lose your footing.
Never work from a ladder as the reaction force of
the jetting gun could cause the ladder to fall
backwards from the working area causing possible
injury.
Never work from scaffolding unless it is designed,
erected and managed by competent persons and it
is adequately secured to prevent it being pushed
over by jetting gun reaction forces.
When using the jetting gun to clean hard surfaces
be aware that splash back could contain hard debris
travelling at speed.
When using the jetting gun to clean contaminated
surfaces be aware that splash back could contain
dangerous contaminants.
Never use the jetting gun to clean a surface that
could be damage or penetrated by the water
pressure unless that is the desired effect.
Flowplant P Pump Manual Issue 9
8
POTENTIAL HAZARDS AND MISUSE OF HIGH PRESSURE EQUIPMENT CONT’D
Failure to follow the instructions where this icon
is shown can result in serious injury or even death
Always ensure that an adequate area is cordoned
off around the working zone so that flying debris
and contamination cannot injure passers-by.
Be aware that the use of water jetting guns fitted with
oscillating or rotating heads tend to produce higher hand
arm vibration levels than simple fixed head jets.
When using a jetting gun or nozzle to clean at floor level
wear suitable protective foot wear.
Never use a high pressure jetting gun to
clean down PPE whilst you or others are
still wearing it as serious injury and death
could result.
Never use a high pressure jetting gun to
wash or cool down livestock as serious
injury and death could result.
Drainage systems may carry bacteria and
micro-organisms which can cause severe illness or death.
Avoid exposing eyes, nose, mouth, ears, hands, cuts or
abrasions to waste water or faecal matter during drain
cleaning operations. After working around drainage
systems help protect yourself by always washing hands.
Personal Protective Equipment (PPE)
All persons using high pressure water jetting equipment
should use all necessary PPE suitable for the task being
carried out. This includes, but is not limited to:
Ear protection
Eye protection: a helmet with chin guard and visor
is recommended
Hand protection
Waterproof clothing
Safety boots with toe protection
Please note: A site specific risk assessment must be
completed to analyse which PPE must be worn.
Flowplant P Pump Manual Issue 9
9
SECTION 1
TECHNICAL DATA
Flowplant P Pump Manual Issue 9
10
SECTION 1
TECHINCAL DATA
CONTENTS
Para
Introduction 1
Pump Description
Function 4
Filtration 9
Fluid Flow 10
Pump Barrel Options
'P' and 'High Lift' Barrels 11
Identity
Manufacturer 16
Pump Identification 17
Design and Performance Data
Physical Data 18
Performance Characteristics 19
Equipment Details 20
Associated Publications 21
ILLUSTRATION
Fig Page
1.1 Harben 'P' Type High Pressure Pump 19
TABLES
Table Page
1.1 Pump Performance Data - Maximum Working Pressures 15
1.2 Performance Data - 'P' Type Pump and Horsepower Required 16
1.3 Performance Data - High Lift Pump and Horsepower Required 17
1.4 Equipment Serial Numbers and Jet Sizes 18
Flowplant P Pump Manual Issue 6
11
TECHNICAL DATA
INTRODUCTION
1. The Harben 'P' Type high pressure pump (Fig 1.1) is a radial piston diaphragm pump which can
be used for a number of industrial applications, including the following:
(1) High pressure cutting of board, plastic and other materials
(2) Water hydraulic systems
(3) Abrasive blasting and descaling
(4) Drain/sewer cleaning
(5) Tube descaling
(6) Desalination by reverse osmosis
(7) Pumping demineralised water
(8) Floor and surface cleaning
(9) Underwater cleaning.
2. In addition to its reliability and long service intervals, the advantages of using this type of pump
include:
(1) Variable pressure and flow options without piston change
(2) Pumps can run dry without damage as there are no piston seals
(3) Filtration of 50 to 150 microns
(4) No modification is required to pump sea water
(5) Pump has multi-cylinders therefore no pulsation
(6) Positive displacement thus high efficiency.
3. The pump is designed to be directly-coupled and flange-mounted, and can be supplied in either
bare-shaft form, or skid mounted, trolley mounted, trailer mounted or truck mounted
configurations. In addition, the pump can be mounted on an underwater ROV. Diesel drive,
electrical drive and hydraulic drive options are available.
Flowplant P Pump Manual Issue 9
12
PUMP DESCRIPTION
Functional
NOTE The following description of the Harben 'P' Type Pump applies equally to the 'High-Lift' variant
of the pump. Performance details of each type of pump are given later in this section.
4. The 'P' pump works on the radial piston design principle which uses one-way valves in
conjunction with tubular diaphragms, fitted with an internal support or mandrel. The pumped
fluid, which passes through this diaphragm, is enclosed by a cylindrical pressure chamber or
barrel, in the ends of which are fitted inlet and delivery valves.
5. The pump crankcase, which contains the only moving parts, is filled with mineral hydraulic oil.
This oil provides for the lubrication of all moving parts within the crankcase, and as a means of
pressure to compress the diaphragm.
6. As the pump shaft rotates, the piston advances and its ports pass the end of the cylinder, sealing
the chamber. Further advance of the piston causes the trapped oil to compress the diaphragm
around the mandrel, expelling the water in the diaphragm through the delivery valve and into
the delivery manifold.
7. When the piston retreats, the diaphragm reverts to its tubular form and draws water through
the inlet valve. Any oil slippage past the piston during the delivery stroke is made up through the
piston ports as they open to the crankcase oil.
8. All mechanical parts, with the exception of the inlet and delivery valves, run in the oil-flooded
crankcase and are therefore unaffected by contamination by the pump fluid, or by running dry.
Filtration
9. Standard filtration for the pump is normally between 50 and 150 microns. This filter is usually
fitted to the inlet of the supply tank or reservoir. This arrangement ensures that if the filter is
neglected to the point of blockage, the tank will empty and the pump will run dry, thus enabling
the dry-running qualities of the pump to be used as a filter maintenance indicator. Inlet
conditions required are flooded suction; pressure feeding is not necessary.
Fluid Flow
10. Arrangements are made on the pump for the incoming fluid to cool the crankcase oil. The use of
standard diaphragm/barrel assemblies provides a choice of flows, depending upon the number
of barrels fitted to a crankcase. The cylindrical form of these barrels is well suited to containing
high pressures. Three piston diameters are available to suit a range of pressure up to 420 bar
(6000 psi).
Flowplant P Pump Manual Issue 6
13
PUMP BARREL OPTIONS
‘P’ and 'High Lift' Barrels
11. 'P' and 'High Lift' type barrels now come in one material EN57 (Spec 431 529) stainless steel for
pressures up to 415 bar (6000 psi).
12. The barrels are always supplied as an assembly including baffle plate (part no 012 001), seal
(011-011) and inner cylinder. The diameter of the cylinder varies for different pump
performances. Diameters available are 18 mm, 20 mm and 22 mm.
13. All barrels are given a letter code to indicate their position in the crankcase (refer to Section 4,
Fig 4.2). This letter code can be found stamped on the face adjacent the inner cylinder. Letters A
to M are used. Each letter is given a part number.
14. When ordering spare barrels, each part number requires cylinder diameter and barrel material
letter options. The option code is shown as two letters. The first indicates the barrel material - A
is for EN57 and B is for EN1A. The second indicates the cylinder diameter - A is for 18 mm, B is
for 20 mm and C is for 22 mm.
15. The part numbers for barrels are as follows (it should be noted that pistons are ordered
separately):
Key:
Barrel material
A = EN57
B = EN1A (This option has been withdrawn)
Cylinder diameter
A= 18mm
B = 20mm
C = 22mm
For example '011-252AB' is a 'C' barrel in EN57 ST/ST with 20 mm cylinder.
Barrel Part No.
Letter Code
011-250
Barrel
'A'
011-251
Barrel
'B'
011-252
Barrel
'C'
011-253
Barrel
'D'
011-254
Barrel
'E'
011-255
Barrel
'F'
011-256
Barrel
'G'
011-257
Barrel
'H'
011-258
Barrel
'J'
011-259
Barrel
'K'
011-260
Barrel
'L'
011-261
Barrel
'M'
Flowplant P Pump Manual Issue 9
14
IDENTITY
Manufacturer
16. The Harben Pumps are manufactured by:
Flowplant Group Ltd.
Gemini House
Brunel Road
Churchfields Industrial Estate
Salisbury
Wiltshire, SP2 7PU
ENGLAND Tel: +44 (0)1722-325424 Fax: + 44 (0)1722-411329
Pump Identification
17. A pump specification label is fitted on the pump crankcase, adjacent to the oil filler cap. This
label will give the pump type (no. of cylinders, piston/cylinder diameter, standard or high lift,
and barrel material).
For example:
The label also gives the pump serial number, the type of oil to be used (Shell Morlina or equivalent), the
maximum working pressure (std - 1000 rpm, high lift - 1250 rpm), the maximum working flow, and the
pump's year of manufacture.
DESIGN AND PERFORMANCE DATA
Physical Data
18. Pump diameter - 405 mm
Pump length - 385 mm
Inlet - 28.6 mm dia
Outlet - 1/2 in SSP
Shaft diameter - 30 mm
Shaft length - 65 mm
6
-
22
-
H
-
S
no. of cyl
piston/cyl dia.
high lift
ST/ST
Flowplant P Pump Manual Issue 6
15
Performance Characteristics
19. For full details of the 'P' and High Lift Pump performance data, reference should be made to the
appropriate information given in Tables 1.1, 1.2 and 1.3.
TABLE 1.1 PUMP PERFORMANCE DATA - MAXIMUM WORKING PRESSURES
Pump/Cylinder
Diameter
'P' 1000 rpm
High Lift 1250 rpm
EN1A
EN57
EN1A
EN57
18 mm
4000 psi
(280 bar)
6000 psi
(420 bar)
4000 psi
(280 bar)
6000 psi
(420 bar)
20 mm
4000 psi
(280 bar)
5000 psi
(350 bar)
4000 psi
(280 bar)
5000 psi
(350 bar)
22 mm
4000 psi
(280 bar)
4000 psi
(280 bar)
4000 psi
(280 bar)
4000 psi
(280 bar)
(1) EN1A and EN57 denote barrel materials. EN1A is mild Steel with a Cadmium plating, whilst
EN57 is Stainless Steel - self finish. (EN1A barrels have now been withdrawn and replaced
with EN57)
(2) As a rule electrically-driven pumps run at 1000 rpm and diesel-driven pumps run at 1250
rpm.
(3) Quantity of cylinders does not alter pump working pressure.
Equipment Details
20. Details relevant to the pump and associated equipment should be entered on the form shown in
Table 1.4, at the rear of this section, for future reference.
ASSOCIATED PUBLICATIONS
21. Associated with this manual are the following publications:
Operators Guide - Part No. 061-225
Code of Practice - Part No 057-062
Guide Do and Dont Booklet - Part No. 081-259
NOTES
Flowplant P Pump Manual Issue 7
16
TABLE 1.2 PERFORMANCE DATA 'P' TYPE PUMP HORSEPOWER REQUIRED
Flowplant P Pump Manual Issue 7
17
TABLE 1.3 PERFORMANCE DATA HIGH LIFT TYPE PUMP HORSEPOWER
REQUIRED
Flowplant P Pump Manual Issue 7
18
TABLE 1.4 EQUIPMENT SERIAL NUMBERS AND JET SIZES
Pump Type
…………………………………….
Pump Serial No(s)
………………………..
Engine Type
…………………………………….
Engine Serial No
………………………..
Gearbox Type
…………………………………….
Gearbox Serial No
………………………..
Motor Frame/kW
…………………………………….
Motor Serial No
………………………..
Maximum Working Pressure of pump
...........................………………………………………….…………..
Maximum Flow at Above Pressure
………………………………………………………………………………..
Single Gun High Velocity Jet Size
…………………………………………………………………………………
Single Gun 15 Degree Jet Size
…………………………………………………………………………………
Twin Gun High Velocity Jet Size
…………………………………………………………………………………
Twin 15 Degree Fan Jet Size
…………………………………………………………………………………
Twin Gun Choke Size
…………………………………………………………………………………
Type of Safety Gun Supplied
…………………………………………………………………………………
Standard Drain Jets
3 Rear drain jet
………………………………………………………………………………..
6 Rear drain jet
………………………………………………………………………………..
3 Rear 1 forward drain jet
………………………………………………………………………………..
High Efficiency Drain Jets
3 Rear HE drain jet
………………………………………………………………………………..
6 Rear HE drain jet
………………………………………………………………………………..
3 Rear 1 forward HE drain jet
………………………………………………………………………………..
Mini Jet Kit 20 ………………………………….
50’……………………………………
Turbo/Dia 38mm Screma Jet
…………………
Dia 16mm Screma Jet ………………………………………………
Jet Leader ………………………………………………………………………………………………………………………………………….
Plough Jet ………………………………………………………………………………………………………………………………………….
Jet Pump……………………………….
Type……………………
Jet sizes…………………..
Hoverclean ………………………………………………………………………………………………………………………………………..
Hovervac …………………………………………………………………………………………………………………………………………
This pump unit and all the accessories listed above have been test at:
…………………………………………………………………….bar
psi……………………………………..……………………………….
Flowplant P Pump Manual Issue 7
19
Fig 1.1 Harben 'P' Type High Pressure Pump
61
63
4
3
6
5
3
6
77
W
13
33
25
26
41
41a
ST/ST
OPTION
15
16
44
44a
ST/ST
OPTION
18
59
73
74
64
66
65
61
63
83
73
74
65
64
66
61
63
83
W
33
013-017
023-087
023-093
013-015
100-290
100-648
15-16
3-6
4-5
18
64
65
Flowplant P Pump Manual Issue 7
20
SECTION 2
PUMP INSTALLATION
Flowplant P Pump Manual Issue 7
21
SECTION 2
PUMP INSTALLATION
CONTENTS
Para
Introduction 1
Pump Mounting
General Details 2
Pump Fitting 7
Pump Access 8
Coupling Arrangements 9
Inlet Water
General 10
Hot Water Conversion Kit 15
ILLUSTRATIONS
Fig Page
2.1 Pump Installation - Pump Mounting 23
2.2 Pump Installation - Pump Access 24
2.3 Pump Installation - Coupling/Gearbox Arrangements for Diesel Drive 25
2.4 Pump Installation - Coupling Arrangements for Electric Drive 26
Flowplant P Pump Manual Issue 7
22
PUMP INSTALLATION
INTRODUCTION
1. It may be the case that the pump has not been purchased as part of a trailer or skid. The
information given in this section is intended to enable customers to install the pump package in
a frame of their design. It will enable engineers to carry out preliminary design work before
submitting the design for Flowplant Group approval. Refer to Section 1 for technical data and a
description of the pump.
PUMP MOUNTING
General Details
2. The 'P' and High Lift pumps are designed for direct drive and flange mounting. The normal
operating speeds are 960 rpm for the 'P' pump and 1250 rpm for the High Lift pump. Maximum
operating speeds are 1000 rpm for the 'P' pump and 1250 rpm for the High Lift pump. The
pumps can rotate either clockwise or anticlockwise, as required. The maximum inlet water
pressure for the pump is 0.5 bar (5.0 metre head), whilst the maximum oil pressure for the
pump is 4.0 metre head to centre line of pump.
3. The pump can be inclined between horizontal and 45 degrees (delivery end uppermost). If
further inclination is required, between 45 degrees and vertical, Flowplant Group Ltd should be
contacted at the address given in Section 1.
4. The weight of a pump with oil in the crankcase, drive coupling fitted and bell housing, depends
on the number of cylinders fitted, as follows:
8 cyl - 80 kg 6 cyl - 68 kg
4 cyl - 58 kg 3 cyl - 51 kg
5. The engineer should ensure that all couplings are fitted with a 3 mm clearance. Where a bell
housing (pump mounting and coupling shaft and cover) cannot be fitted due to a difference in
spigot or bolt locations, an adaptor ring may be fitted.
6. It is recommended that a detailed layout be drawn and the following points considered:
a. Selection of hell housing most suitable for adaptor ring. Additional machining to the bell
housing may be required.
b. Sufficient coupling engagement on the shaft whilst maintaining the recommended
clearance.
c. Clearance between shafts; careful design can eliminate the shortening of motor/engine
shaft. Pump Fitting. (Fig 2.1)
Flowplant P Pump Manual Issue 7
23
Pump Fittings
7. When the pump is to be fitted in position, the following points should be noted:
a. When the pump is first married up to the prime mover, access is required to check
coupling clearance. When Flender 8140 couplings are used, sight/gauge holes are drilled
in the bell housing for this purpose.
b. Where pumps are fitted with either a pressure gauge or selector (not shown on Fig 2.1)
sufficient access must be allowed for sight or operation. If this is impracticable, a remote
pressure gauge and selector are recommended.
c. It depends on the particular installation whether the pump head is removed to a
workshop for maintenance, e.g. diaphragm or valve replacement or whether work is
carried out in-situ. See also Fig 2.2 Note.
d. Where a pump 'strip-down' is required, the pump should be removed to the workshop.
The use of an assembly stand is recommended.
Fig 2.1 Pump Installation Pump Mounting
Flowplant P Pump Manual Issue 7
24
Pump Access
8. Reference should be made to Fig 2.2 for the pump access requirements. In addition, access is
also required to the pressure disc (Fig 2.1). A withdrawal distance of at least 25 mm should be
allowed for removal of the inlet manifold.
NOTE: IT MAY BE NECESSARY FOR THE PUMP HEAD TO BE REMOVED TO CHANGE VALVES AND
DIAPHRAGMS. ACCESS IS NOT AVAILABLE ON ALL UNITS FOR THE FITTING OF A SOCKET AND
TORQUE WRENCH TO THE INLET NUTS, THUS IF A SOCKET CANNOT BE USED, THEN THE HEAD
MUST COME OFF. ON SOME UNITS, UNLESS THE BELL HOUSING IS REMOVED, IT IS IMPOSSIBLE
TO FIT A SOCKET.
Fig 2.2 Pump Installation Pump Access
Flowplant P Pump Manual Issue 7
25
Coupling Arrangements
9. For details of the engine/gearbox coupling arrangements for diesel-driven pumps refer to Fig
2.3. For details of the coupling arrangements for electrically-driven pumps refer to Fig 2.4.
* 012-159 when 019-020, 8 x 22, 3516 option is selected.
Fig 2.3 Pump Installation Coupling/Gearbox Arrangements for Diesel Drive
Engine
Gearbox
Output
Coupling
Gearbox
Gear Input
Coupling
Engine
Drive
Flange
Adaptor
Plate
Flywheel
Adaptor
Ring
Flender
Flexibles
Ford FSD
016-020
012-160*
016-032
016-054
N/A
N/A
016-014
Perkins 3.152
016-020
012-160*
016-032
016-001
016-038
012-146
016-014
Lister TX2/3
016-020
012-159
016-037
016-036
N/A
012-183
016-034
Harz 3L40C
016-020
012-160
016-030
016-031
N/A
012-194
016-014
Kubota V1505
016-020
012-159
016-096
016-095
N/A
012-213
016-014
Lister LPWS3
016-020
012-159
016-032
016-107
N/A
012-213
016-014
Flowplant P Pump Manual Issue 7
26
MOTOR HALF COUPLINGS FOR ELECTRIC MOTORS
(Metric Frame Non-hazardous Types)
Part Number
Description
023-094
7.5 HP Motor coupling B140 Pt 1
023-034
10 HP Motor coupling B140 Pt 1
023-034
15 HP Motor coupling B140 Pt 1
023-036
20 HP Motor coupling B140 Pt 1
023-037
25 HP Motor coupling B140 Pt 1
023-037
40 HP Motor coupling B140 Pt 1
Fig 2.4 Pump Installation Coupling Arrangements for Electric Drive
Flowplant P Pump Manual Issue 7
27
INLET WATER
General
10. It is recommended that inlet water is filtered to between 50 and 150 microns. Flowplant Group
offer types of filter suitable for most applications.
11. Turbulent water will cause the pump to run unevenly and cause excessive wear due to
cavitations. For this reason, water must first pass through a break water or header tank
controlled by a ball valve or float device. Water leaving the tank should have lamina flow
characteristics and be air free.
NOTES (1) If water is filtered before the tank, then the tank must be sealed and vented to avoid
contamination.
(2) A pressure/flow check at the inlet to the pump is recommended. The maximum inlet
water pressure for the pump is 0.5 bar (5.0 metre head).
12. A pH value of 5 to 9 is recommended. Although liquids outside this range may occasionally be
pumped, it is advisable to contact Flowplant Group, at the address given in Section 1, for their
advice.
13. Hose and pipe bores between the break water tank and pump should be a minimum of 32 mm
(1 ¼in) and up to a length of 1 metre. If a longer length of hose/pipe is required, refer to the
nearest authorised dealer.
14. Other points to be considered concerning inlet water are:
a. Avoid long hose or pipe runs.
b. Avoid hose or pipe runs that cause air pockets.
c. Refer to circuit layout for mounting angle of pump.
d. If water inlet temperature is over 25°C, consult the nearest authorised dealer (unless
70°C Hot Water Conversion Kit is fitted - see Para 15).
Hot Water Conversion Kit
15. A Hot Water Harben 'P' Pump Conversion Kit (Part No. 009-001) is available to enable hot water,
up to 70°C, to be used with the pump.
Flowplant P Pump Manual Issue 7
28
16. A conversion kit is available for each barrel. The number of conversion kits required equals the
number of barrels in the pump supplied. The conversion kit comprises the following items:
Per Barrel Part No. Qty
CASTING MANDREL P TYPE HIGH TEMP WATER INLET 009-002 1
VALVE INLET FOR HIGH TEMP WATER INLET 009-004 1
VALVE DELIVERY HIGH TEMP WATER INLET 009-005 1
BARREL 0-RING VITON BS135/60 P-TYPE 009-008 2
O-RING END PLATE VITON "103"70 SHORE 1150MM LG VIT 009-009 1
O-RING CENTER VITON BS036/70 009-010 2
O-RING COOLER VITON BS122/70 009-011 2
Per pump Part No. Qty
HOT WATER PUMPING P-PUMP 'O' RING KIT 009-016 1
KIT - HOT WATER CONVERSION - 8 CYL P TYPE PUMPS 009-102 1
KIT - HOT WATER CONVERSION - 6 CYL P TYPE PUMPS 009-103 1
KIT - HOT WATER CONVERSION - 4 CYL P TYPE PUMPS 009-104 1
KIT - HOT WATER CONVERSION - 3 CYL P TYPE PUMPS 009-105 1
17. Depending on the water hardness, it may be necessary to install an industrial descaler in the
water tank to prevent a build-up of scale.
18. One point to consider when converting a pump, and subsequently working out a maintenance
program, is that pump bearing life will be significantly reduced. This will need to be considered
in the maintenance program.
Flowplant P Pump Manual Issue 7
29
SECTION 3
GENERAL OPERATING
INFORMATION
Flowplant P Pump Manual Issue 7
30
SECTION 3
GENERAL OPERATING
INFORMATION
CONTENTS
Para
Introduction 1
Safety Code of Practice 2
General 5
Safety Gun 6
Drain/Sewer and Pipe Cleaning 7
Hoses 8
Underwater Recoil-less Safety Gun 9
Tube Cleaning 10
Hoverclean 11
Abrasive Injection Equipment 12
Accidents 13
Protective Equipment 14
General Operating Instructions
Introduction 15
Starting 16
Stopping 17
To Oil Bleed the Pump 18
To Water Bleed the Pump 19
To Anti-Freeze a Unit Without an Anti-Freeze Tank 20
To Remove Anti-Freeze From a Unit Without an Anti-Freeze Tank 21
To Anti-Freeze a Unit With an Anti-Freeze Tank Fitted 22
To Remove Anti-Freeze From a Unit With an Anti-Freeze Tank Fitted 23
Fault Finding
General 24
ILLUSTRATIONS
Fig Page
3.1 Bleeding the Pump 36
3.2 Pump Fault Finding - Diaphragm Failure 41
TABLES
Table Page
3.1 Equipment Fault Finding 39-40
3.2 Pump Fault Finding 42
Flowplant P Pump Manual Issue 7
31
GENERAL OPERATING INFORMATION
INTRODUCTION
1. This section gives general information on safety, protective clothing to be used by operators,
and general starting and stopping procedures when the pump is incorporated in equipment. It
should be remembered that the operating procedures given are to be used as a guide only and
the equipment handbook operating procedures should be used where applicable.
SAFETY CODE OF PRACTICE
BASIC RULES
1. ALWAYS WEAR THE CORRECT PROTECTIVE CLOTHING.
2. ALWAYS ENSURE ALL EQUIPMENT IS IN A FIRST CLASS CONDITION,
3. NEVER WORK FROM A LADDER.
4. NEVER USE THE GUN WITH THE TRIGGER LOCKED ON.
5. NEVER POINT THE GUN AT ANYONE, EVEN IF SWITCHED OFF.
2. This Code of Practice is intended to provide guidance on the safe operation of high pressure
water jetting equipment.
3. The term 'high pressure water jetting' covers all water jetting, including the use of additives and
abrasives, where there is an energy input to increase the pressure of water.
4. This code applies to high pressure water jetting as defined above where there is a foreseeable
risk of injury.
General
5. (1) Only a responsible person who has received instruction in the operation of high pressure
water jetting equipment should be allowed to operate the equipment.
(2) Barriers should be erected around the cleaning bay or where the work is being done 'in-situ',
round the section of plant concerned. Access within 10 metres by persons other than the jetting
team, is strictly prohibited.
(3) A warning notice 'NO UNAUTHORISED ENTRY High Pressure Water Jetting in Progress' should
be displayed on each side of the bay, or on the plant, where the work is to be done.
(4) Each member of the team should be provided with suitable waterproof clothing, wellington
boots with internal steel toe caps, safety helmet with visor and earmuffs, and gloves. Refer to
Para 14 for details of protective clothing available.
Flowplant P Pump Manual Issue 7
32
SAFETY CODE OF PRACTICE (Cont'd)
General (Cont'd)
(5) Never attempt to change jets or accessories whilst the pump is operating, even if the flow
control selector valve is in the recycle (dump) position.
Safety Gun
6. (1) Never point the safety gun at anyone, even if it is switched off.
(2) When using the 'deadmans handle' safety gun, the required jet should be fitted to the high
pressure barrel (low pressure barrel is fitted with a diffuser) and tightened correctly before
starting the unit. All other hose connections, etc must be checked before attempting to start the
unit.
(3) Water jetting guns should be properly maintained and care should be taken not to damage
the delicate components of the trigger mechanism.
Drain/Sewer and Pipe Cleaning
7. (1) In addition to the protective clothing listed in Para 5(4), the other equipment should be used
when entering confined spaces, such as safety harness and rescue line, atmospheric testing
equipment, escape breathing apparatus and hand lamps (intrinsically safe where appropriate).
(2) To prevent snaking or reverse travel of a flexible hose inside the tube being cleaned, a
section of steel pipe, slightly longer than the diameter of the tube to be cleaned, should be
connected between the flexible hose and the nozzle (drain jet extension).
(3) During drain cleaning operations it is advisable to use a coloured leader hose to act as a
warning to the operator that the hose recovery is almost complete.
(4) Where drain or pipe jetting operations are to be carried out remote from the high pressure
pump unit, i.e. where communication between the person controlling the pump and the
equipment operator is not possible, it is essential that a remote control kit or foot control valve
is used at the work point.
Hoses
8. (1) Care should be taken to ensure that all hoses are maintained in good condition and are of
the correct specification for the pressure being used.
(2) Never loop the hose into an excessively tight radius, particularly adjacent to couplings.
(3) When fitting re-usable couplings, always ensure that the correct type of couplings are being
used in relation to the hose specification.
Flowplant P Pump Manual Issue 7
33
SAFETY CODE OF PRACTICE (Cont'd)
NOTE The equipment detailed in Para’s 9, 10, 11 and 12 are for specialist applications.
Underwater Recoil-less Safety Gun
9. (1) The Harben Underwater Recoil-less Safety Gun is designed for use under water only. Extreme
care should be taken to avoid rear-facing balance jets when testing the equipment above water.
(2) If working in shallow water, where there is a possibility of the diver surfacing inadvertently
during water blasting, care should be taken to ensure that the recoil balance jet protection tube
is sufficiently long to prevent the diver directing it at himself.
Tube Cleaning
10. (1) Where tube cleaning is to be done by means of a lance, the charge-hand who operates the
remote control valve should first insert the lance into the tube, leaving the other end of the
lance supported by one man. Once the tube has been inserted, the other men required to
support the control lance should take up their places, and only then should the charge-hand
operate the valve.
NOTE When the person operating the remote control valve is unable to speak directly
to the man, or men, controlling the lance, a clearly understood system of signals and
instructions must be agreed upon.
(2) A barrier should be placed at the far end of the tube being cleaned for protection against
flying debris.
(3) A shield fitted to the lance to protect the operator from debris ejected by backward pointing
jets should be used for certain operations.
Hoverclean
11. (1) The angle of the jet holders determine the rotational speed of the spray bar; this is set and
locked in position at the works, and on no account must this angle be altered.
Abrasive Injection Equipment
12. (1) Because water/abrasive jetting can give rise to dangerous splash back, ensure all protective
clothing, detailed in Para 5(4), is used. Some abrasives are known to produce residues which
may be hazardous to health and should not be used for blasting, such as sand containing free
silica.
Accidents
13. (1) In the event of a person being injured by the impact of a water jet, the injury caused may
appear insignificant and give little indication of the extent of the injury beneath the skin and the
damage to deeper tissues. Large quantities of water may have punctured the skin, flesh and
organs through a very small hole that may not even bleed.
Flowplant P Pump Manual Issue 7
34
SAFETY CODE OF PRACTICE (Cont'd)
Accidents (Cont'd)
(2) Operators should carry a card which explains to medical staff the possible nature of the
injury, both relating to the high pressure water and any unusual infections that may be found in
sewage, such as Leptospirosis, better known as Weirs Disease.
PROTECTIVE EQUIPMENT
14. A range of top quality protective equipment is available from Flowplant Group Ltd, as follows:
Part Number
Description
061-037
Suit Waterproof Coverall - size small
061-025
Suit Waterproof Coverall - size medium
061-026
Suit Waterproof Coverall - size large
061-020
Suit Waterproof Coverall - size extra large
065-076
Metatarsal Safety Boots size 6
065-061
Metatarsal Safety Boots size 7
065-060
Metatarsal Safety Boots size 8
065-057
Metatarsal Safety Boots size 9
065-058
Metatarsal Safety Boots size 10
065-066
Metatarsal Safety Boots size 11
065-065
Metatarsal Safety Boots size 12
065-062
Gauntlet Gloves
065-013
Complete Helmet Set
061-054
‘No Unauthorized Entry High Pressure
Jetting In Progress’ Safety Sign
061-225
Operators Safety Guide
057-062
Safety Code of Practice
061-445
Code of Practice (Sewer Drain Jetting)
061-259
Guide Do and Don’t Booklet
Flowplant P Pump Manual Issue 7
35
GENERAL OPERATING INSTRUCTIONS
Introduction
15. The following operating instructions are of a general nature with reference being made to the
appropriate manufactures handbook for the machine. The machine should be in the shut down
position.
Starting
16. To start the unit, carry out the following instructions:
(1) Prior to starting the unit, carry out the following pre-checks:
i. Set the high pressure selector to the recycle (dump) position.
ii. Ensure engine/motor is switched off.
iii. Ensure the unit is on level ground.
iv. Check that the water supply is connected and the header tank is full.
v. Check that all guns and nozzles are connected. Ensure correct fitting and correct
size for the pressure required.
(2) Start the unit. Refer to the manufacturer's handbook for information concerning
engine/electric motor starting procedure.
NOTE Before starting the unit and carrying out water and/or oil bleed operations (refer to Paras
18 and 19, respectively), familiarise yourself with the units controls and the stopping
instructions (Para 17).
(3) Move the selector to the High Pressure position.
Stopping
17. To shut down the unit, carry out the following instructions:
(1) Reduce engine revs to tick-over speed.
(2) Move the high pressure selector to the recycle (dump) position.
(3) Switch off the prime mover by following the instructions given in the manufacturer's
handbook for the engine/electric motor.
(4) If there is the risk of freezing, follow the instructions given the frost precautions (anti-
freeze procedures, Paras 20 or 22).
(5) If the unit is to be stored for more than 7 days without running, an inhibitor should be
Flowplant P Pump Manual Issue 7
36
run through the system. Do not drain prior to storage; always leave full of fresh water or
inhibitor.
(6) Refer to the manufacturer's handbook for information concerning engine/ electric motor
protection/storage.
To Oil Bleed the Pump
18. As delivered from the factory, the pump would have already been oil bled (except pump heads
supplied separately). If necessary, oil bleed the pump as follows:
NOTE Refer to the lubrication chart given in Section 4, Table 4.2 for details of pump oil types and
capacities.
(1) Fill the pump to the top of the crankcase with the correct oil; the top of the oil cooler
should just be visible (or ensure oil is in the expansion bottle, if fitted). To identify the oil cooler,
refer to Item 11 on the drawings located Section 4.
(2) Set the selector valve to the recycle (dump) position and start the engine/ motor. Run at
750 rpm tick-over to prime, or inch electric motor (on/off).
NOTE If the unit is fitted with a shut-down protection device, hold in the override button for 10
seconds (this allows the engine oil pressure to build up).
(3) With reference to Fig 3.1, put a finger on top of an oil bleed screw on a lower barrel and
open the screw slowly using a suitable spanner. When air-free oil flows, tighten the bleed screw
firmly.
NOTE Top up oil in the pump crankcase after each barrel has been bled.
(4) Repeat the procedure detailed in sub-pars (3) for each barrel, starting from the lower barrels
first.
Fig 3.1 Bleeding the Pump
Flowplant P Pump Manual Issue 7
37
(5) When the operator has taken up a working position, move the selector lever to the High
Pressure position and increase engine speed to reach working pressure.
(6) If the delivery line vibrates or the pump does not run smoothly, stop the unit and carry out a
water bleed (Para 19) and then repeat the oil bleed.
To Water Bleed the Pump
CAUTION ON NO ACCOUNT OPEN THE WATER BLEED SCREWS WHEN THE PUMP IS OPERATING
UNDER PRESSURE.
19. Whenever the unit is started after being allowed to run dry, the following procedure must be
followed:
(1) Set the selector valve to the recycle (dump) position and start the engine/ motor. Run at 750
rpm tick-over to prime, or inch electric motor (on/off).
NOTE If the unit is fitted with a shut-down protection device, hold in the override button for 10
seconds (allows engine oil pressure to build up).
(2) The pump is self-priming. If, however, any difficulty is experienced, stop engine, loosen the
upper bleed nipples and allow water to flow from each nipple (ensure that the header tank
remains full). Tighten nipples and repeat the procedure detailed in sub-pars (1). To identify the
bleed nipples, refer to Item 72 on the drawings located Section 4.
(3) When the operator has taken up a working position, move the selector lever to the High
Pressure position and increase engine speed to reach working pressure.
NOTE If the delivery line vibrates this indicates that air is still in the system. Stop the unit and repeat
the procedure detailed in sub-pars (1).
To Anti-Freeze a Unit without an Anti-Freeze Tank
20. (1) Prepare 5 gallons (or larger quantity if required) of 30% to 50% anti-freeze solution.
(2) Drain the water tanks.
(3) Pour the anti-freeze solution into the break tanks.
(4) Remove any jet or accessory from the end of the high pressure hose.
(5) Ensure the high pressure selector lever is in the dump (or off) position. Start the engine and
allow to run for 1 minute,
(6) Holding the outlet end of the hose, move the selector to high pressure position and allow the
engine to run until the anti-freeze solution can be seen coming from the high pressure hose.
(7) Stop the engine. The unit is now anti-freezed.
Flowplant P Pump Manual Issue 7
38
To Remove Anti-Freeze From a Unit without an Anti-Freeze Tank
NOTE During this procedure, carry out the air bleed procedure detailed in Para 19, if necessary.
21. (1) Drain any anti-freeze solution from break tanks into a container.
(2) Fill break tanks with water,
(3) Place the outlet of the high pressure hose into the container.
(4) Place the selector lever in the high pressure position, and whilst holding the high pressure
hose, start the engine.
(5) Run the engine until all solution is returned to the container and clean water is seen flowing
from the hose. The unit is now ready to use.
To Anti-Freeze a Unit with an Anti-freeze Tank Fitted
22. (1) Ensure the anti-freeze tank is full of 30% to 50% anti-freeze solution.
(2) Turn the 3-port valve to the anti-freeze position and open valve on the anti-freeze tank (if
fitted).
(3) Remove any jet or accessory from the end of the high pressure hose.
(4) Move the selector lever to the high pressure (or on) position.
(5) Holding the end of the hose, start the engine.
(6) Allow engine to run on tick-over until the anti-freeze solution can be seen coming from the
high pressure hose.
(7) Move the selector to the recycle (dump) position for 5 seconds (this allows the dump hose to
be anti-freezed).
(8) If Jump Jet or Remote Control kits are fitted, ensure they are anti-freezed. The unit is now
anti-freezed.
To Remove Anti-Freeze from a Unit with an Anti-freeze Tank Fitted
23. (1) Move the 3-port valve to the water position.
(2) Fill the water tanks.
(3) Place the outlet of the high pressure hose into the anti-freeze tank.
(4) Place the selector lever in the high pressure position.
(5) Start the engine. Allow it to run at tick-over and pump anti-freeze solution into the anti-
freeze tank. Stop the engine when clear water is seen flowing out of the high pressure hose. The
unit is now ready to use.
Flowplant P Pump Manual Issue 7
39
FAULT FINDING
General
24. It is essential when fault finding on the pump that due regard is taken of the likely equipment faults.
Therefore, Table 3.1 includes likely equipment faults, whilst Table 3.2 gives likely pump faults. For
details of engine faults refer to the appropriate manufacturer's handbook. When investigating a pump
diaphragm for possible failure, refer to Fig 3.2.
Table 3.1 Equipment Fault Finding
Problem
Cause
Action
Low System Pressure
1. Worn or incorrect size of
cutting nozzle.
2. Engine speed slow.
3. Leaks from hose, pipes
and connections.
4. Blocked inlet filter.
5. Inlet hose too long.
6. Loss of water through
dump line of selector
valve or gun when high
pressure selected.
7. Loss of water through
dump line of remote
control kit, if fitted.
Replace nozzle.
Adjust to correct speed.
Check connections for tightness.
Replace as necessary.
Clean or replace element.
Shorten hose length.
Check seats and seals.
Check seats and seals.
High System Pressure
1. Blocked nozzle, selector
valve or gun.
2. Incorrect nozzle size.
3. Incorrect bore size.
4. Engine speed high.
5. Crushed delivery hose.
6. Two gun choke left in gun
when operating as single
gun unit.
Clean nozzle, selector valve of gun
and flush out delivery line.
Replace nozzle.
Replace nozzle.
Adjust to correct speed.
Replace if necessary.
Replace with standard choke.
Flowplant P Pump Manual Issue 7
40
Problem
Cause
Action
Low Water Level
1. Blocked or dirty pre-
filters.
2. Faulty ball valve assembly.
3. Wrong seat in ball valve
assembly.
4. Low inlet pressure
Clean or replace elements.
Replace if necessary.
Replace if necessary.
Increase pressure.
Pump Not Running Evenly
(also refer to Pump
faults).
1. Air in water.
2. Air in crankcase oil.
3. Worn Coupling
4. Faulty inlet or delivery
valve.
5. Valve nut over tightened.
Water bleed pump ( Para 19)
Oil bleed pump (Para 18)
Replace flexible elements and
examine coupling.
Check valve condition.
Check tightness of inlet and
delivery nut.
Burst Disc Failure or
Safety Relief Valve
Operating (also refer to
high system pressure
problem).
1. Incorrect burst disc.
2. Incorrect valve setting.
3. Faulty Valve.
4. Faulty or fatigued burst
disc.
Replace with correct disc.
Check certificate/setting.
Repair or replace, as necessary.
Replace with new disc.
Table 3.1 Equipment Fault Finding (Cont’d)
Flowplant P Pump Manual Issue 7
41
Table 3.2 Pump Fault Finding
Problem
Cause
Action
1. Mixing of Oil and
Water in
Crankcase.
2. Loss of pressure.
3. Pump not
running evenly.
1. Worn or damaged delivery
valves.
2. Damaged filter element
allowing debris to jam
delivery valve.
1. Check all delivery valves
replace as necessary.
2. Check all diaphragms
replace as necessary.
3. Replace oil.
4. Check filters replace as
necessary.
1. Loss of crankcase
oil through high
pressure hose.
2. Loss of pump
pressure
3. Pump not
running evenly
1. Inlet restriction may have
been caused through;
a. Blocked filters
b. Kinked inlet hose
c. Worn or damaged
inlet valves
d. Excessive inlet hose
length
2. Pump has been frozen
1. Clear restriction.
2. Check inlet valves
replace as necessary.
3. Check diaphragms
replace as necessary.
4. Replenish oil.
1. Mixing of Oil and
Water in
Crankcase.
1. Diaphragm failure (may
have been through fatigue
from excessive running
hours).
1. Check all diaphragms
replace as necessary.
Flowplant P Pump Manual Issue 7
42
Fig 3.2 Pump Fault Finding Diaphragm Failure
Flowplant P Pump Manual Issue 7
43
SECTION 4
PUMP MAINTENANCE
AND
OVERHAUL PROCEDURES
Flowplant P Pump Manual Issue 7
44
SECTION 4
PUMP MAINTENANCE
AND
OVERHAUL PROCEDURES
CONTENTS
Para
Routine Maintenance
Introduction 1
Pump Service Information
General 3
Recommended Service Tools 4
Torque Settings 5
Burst Discs 6
Service Kits 7
Pump Overhaul Procedures
Introduction 8
Removal and Replacement of Pump Head 10
Removal and Replacement of Diaphragms and Valves 11
Pump Strip and Re-Assembly 13
Pump Running In 15
ILLUSTRATIONS
Fig Page
4.1 Inlet Valve Identification 51
4.2 Pump Cylinder Code 54
4.3 'P' Type and High Lift Pump - Pump Assembly 56
4.4 'P' Type and High Lift Pump - Barrel Assembly 57
4.5 'P' Type and High Lift Pump - Pump Cross-Section 58
4.6 'P' Type and High Lift Pump - Pump Parts List 59
4.7 'P' Type and High Lift Pump - Inlet Manifold Assembly 60
4.8 Manifold Selector Assembly 61
4.9(a) Inline Selector Assembly 62
4.9(b) Inline Selector Assembly 63
TABLES
Table Page
4.1 Pump Maintenance Schedule 45
4.2 Pump Lubrication Chart 46
Flowplant P Pump Manual Issue 7
45
PUMP MAINTENANCE AND OVERHAUL PROCEDURES
ROUTINE MAINTENANCE
Introduction
1. The Maintenance Schedule (Table 4.1) gives details of pump maintenance only.
For details of equipment maintenance, refer to the appropriate handbook. Details of pump oil
capacities and recommended oil types are given in the Lubrication Chart (Table 4.2). Refer to the
manufacturer's handbook for diesel engine oil.
2. Whilst specific periods for routine (preventive) maintenance of the pump are given, due regard
should be taken of local regulations concerning the vehicle or machine. Ensure the machine is
operating within those regulations.
Table 4.1 Pump Maintenance Schedule
CHECKLIST
PRIOR TO USE/DAILY/AFTER 8 HOURS RUNNING
Crankcase oil
Pipes, hoses and fittings
Pump working pressure
General
Check for level, fill if necessary (refer to Section 3, Para 18(1) for
procedure and Table 4.2 for oil types).
Check wear, damage, correct rating and size.
Check correct.
Check pump for smooth running, overheating, leaks and security of
components.
Inlet/delivery valves
Diaphragms
SIX MONTHLY/300 HOURS
Check for wear and damage
Check for wear and damage
Crankcase oil
Inlet/delivery valves (‘P’)
Inlet/delivery valves (‘HL’)
Pipes, hoses and fittings
YEARLY/500 HOURS
Drain and renew.
Check for wear and damage.
Replace.
Carry out a detailed inspection.
Inlet/delivery valves (‘P’)
Diaphragms
TWO YEARLY/1000 HOURS
Replace.
Replace.
Flowplant P Pump Manual Issue 7
46
Table 4.2 Pump Lubrication Chart
Manufacturer
Type
Oil Capacity (litres)
ESSO
Nuto H150
Number of Cylinders
GULF
LP 150
3-Cyl
4-Cyl
6-Cyl
8-Cyl
MOBIL
DTE Extra Heavy
6.5
6
5.75
5
ROC
Kiron
TEXACO
Rando HD 150
BP
Energol HLP 150
AGIP
OSO 105
SHELL
Morlina 150
CENTURY OIL
PWLM
PETROFINA
Hydran 51
CASTROL
Hyspin AWS 150
Flowplant P Pump Manual Issue 7
47
PUMP SERVICE INFORMATION
General
3. The following paragraphs give details of recommended service tools, torque settings, burst discs
and service kits to be used when carrying out pump overhaul procedures.
Recommended Service Tools
4. The following tools should be available when servicing the pump:
Description Part Number
Repair stand 042-177
Spanner, open ended, 9/16" whit. x 5/8" whit. 202-048
Spanner, open ended, 19 mm 202-036
Spanner, open ended, 1 3/8" whit. 202-037
Spanner, adjustable, 12" 202-302
Spanner, combination, 4 BA 202-150
Pipe grips 206-102
Hammer, nylon. 1 3/4" dia. 206-001
Allen key, 6 mm 206-103
Pliers, circlip, external, 10-25 mm 205-001
Wrench, 'T' hex, 4 mm 204-002
Screwdriver, flat blade, 10" 206-101
Torque wrench 203-256
Socket, reversible ratchet, 1/2" square drive 203-242
Socket, extension bar 250 mm, 1/2" square drive 203-247
Socket, 1/2" square drive, 11116" 203-129
Socket, 1/2" square drive, 17 mm 203-170
Drift, mandrel 061-044
Dolly, bearing 201-007
Set screws, M8 x 50 mm (6 off) 023-067
Flowplant P Pump Manual Issue 7
48
Torque Settings
5. The torque settings for selected components are:
Drg Item No*
lbft
kgm
Nm
Nut, nyloc, M20 x 1.5
29
100
13.8
135
Valve nut, delivery
44
100
13.8
135
Valve nut, inlet
41
100
13.8
135
Adaptor
49
30
4.1
41
Adaptor
73
29
4.0
39
Set screw
20
20
2.8
27
Set screw
14
40
5.5
54
Holder for Burst Disc
64
25
3.5
34
Banjo bolt
R3
118
16.3
160
* Refer to Para 9 and the drawings in this section to locate Item Number.
Burst Discs
6. When carrying out any maintenance/overhaul of the pump, ensure the correct burst disc, for its
working pressure, is fitted. The available burst discs are as follows:
Colour Code
Part Number
For Maximum
Working Pressure
Yellow
011-019
125 bar (1800 psi)
Blue
011-020
140 bar (2000 psi)
Red
011-021
175 bar (2500 psi)
Purple
011-022
210 bar (3000 psi)
Green
011-045
240 bar (3500 psi)
White
011-046
275 bar (4000 psi)
Black
011-047
345 bar (5000 psi)
Orange
011-107
415 bar (6000 psi)
Service Kits (Kits not available in all countries)
7. Service/overhaul kits are available when carrying out repair or overhaul of the pump. Details of
kits for both the Standard 'P' pump and the High Lift pump are as follows:
NOTE High Lift pumps are identified from Standard 'P' pumps by the letter H being stamped
after the serial number on the pump identification Plate.
a. Standard 'P' Pump Service Kit
Kit overhaul, valve and diaphragm, 3-cyl 'P' pump Part No 023-236
Kit overhaul, valve and diaphragm, 4-cyl 'P' pump Part No 023-237
Kit overhaul, valve and diaphragm, 6-cyl 'P' pump Part No 023-238
Kit overhaul, valve and diaphragm, 8-cyl 'P' pump Part No 023-239
Flowplant P Pump Manual Issue 7
49
Part No Description Quantity
3-cyl 4-cyl 6-cyl 8-cyl
011-060 Valve, delivery 3 4 6 8
011-048 Valve, inlet 3 4 6 8
012-032 Diaphragm 3 4 6 8
b. High Lift Pump - Service Kit (Kits not available in all countries)
Kit overhaul, valve and diaphragm, 3-cyl HL pump Part No 024-024
Kit overhaul, valve and diaphragm, 4-cyl HL pump Part No 024-025
Kit overhaul, valve and diaphragm, 6-cyl HL pump Part No 024-026
Kit overhaul, valve and diaphragm, 8-cyl HL pump Part No 024-027
Part No Description Quantity
3-cyl 4-cyl 6-cyl 8-cyl
011-060 Valve, delivery 3 4 6 8
011-166 Valve, inlet 3 4 6 8
012-032 Diaphragm 3 4 6 8
PUMP OVERHAUL PROCEDURES
Introduction
8. During the pump overhaul procedures, reference should be made to the pump assembly
drawings, including associated Parts List, located at the rear of this section. Also included are
assembly drawings of the inlet manifold and inline and manifold selectors.
9. In the following overhaul procedures, the item number that follows the description of a part
refers to the assembly drawings (Figs 4.3 to 4.6). Where the letter M appears before the item
number, refer to the Inlet Manifold Assembly drawing (Fig 4.7). Where the letter R appears
before the item number, refer to the Manifold Delivery Assembly drawings (Figs 4.8 and 4.9).
Removal and Replacement of Pump Head
NOTE Refer to Para 9 for drawing information.
10. Carry out a removal and replacement of the Pump Head, as follows:
(1) Switch off and isolate the prime mover.
(2) Switch off or disconnect the water mains supply to the tank.
Flowplant P Pump Manual Issue 7
50
(3) Drain the water tank.
(4) Disconnect the water inlet hose to the pump.
(5) Disconnect the high pressure hose from the Delivery Manifold or Selector, as fitted.
(8) Drain water from the base of the Inlet Manifold (12). Replace when drained.
(7) Disconnect the hose Snap Coupling from the top of the Crankcase to oil expansion
bottle, if fitted.
(8) Remove either the Expansion Chamber (4) or the Adaptor from the top of the
Crankcase, and replace with a Lifting Eye (Part No 061-077).
(9) Connect lifting tackle to the Lifting Eye. Po not take the weight of the pump, leave only
slack cable.
(10) Remove the bolts from the bell housing and pull off pump and bell housing.
NOTE If an adaptor ring is fitted, it is usually best to leave it attached to the prime mover.
(11) Before replacing the pump, check the drive coupling stand-off distance.
(12) Replace the pump, generally reversing the removal procedure.
NOTE Before operating the pump, it may be necessary to bleed the pump of air.
(13) If the pump fitted is new or has been overhauled, carry out the running in procedure
detailed from Para 15.
Removal and Replacement of Diaphragms and Valves
NOTES (1) In most cases the work can be carried out on the machine.
(2) Refer to Para 9 for drawing information.
11. Carry out removal of Diaphragms and Valves, as follows:
(1) On the Standard Delivery Manifold uncouple the Top Hose (70 and 71) from Adaptor
(49).
(2) the Inlet Manifold (12), by drawing back the Retaining Ring (M2), opening the Spring
Clip (M4) and pulling the Inlet Manifold evenly off Valve Nuts (41) and Cooler
(1 1).
Flowplant P Pump Manual Issue 7
51
(3) Unscrew the Valve Nut (41) two turns if the Delivery Valve (43) only is to be removed. If
Diaphragm (51) and Inlet Valve (45 or 46) are to be removed, then unscrew the Valve
Nut (41) completely.
(4) Remove Valve Nut (44) completely.
(5) If Diaphragms (51) are to be removed, drain the oil from the pump.
(6) Remove a Diaphragm (51), Mandrel (52) and Inlet Valve (45 or 46 - refer to Fig 4.1) by
placing a drift (Part No 061-044) in the end of the Mandrel at the delivery end of the
Barrel and tapping the drift gently with a mallet.
(7) Remove the Delivery Valve (43) carefully using pipe grips (Part No 206-102).
Fig 4.1 Inlet Valve Identification
Flowplant P Pump Manual Issue 7
52
12. Carry out re-assembly of the Diaphragms and valves, as follows:
NOTE On no account should Diaphragm (51) and Mandrel (52) be fitted as an assembly. If the
Delivery Valve (43) is removed for any reason, or the delivery Valve Nut (44) is slackened, the
inlet Valve Nut (41) must be slackened off two turns and the delivery Valve Nut (44) tightened
before the inlet, Valve Nut (41) is retightened.
(1) Assemble Valves (43 and 45 or 46). Ensure components are clean and all '0' rings are
undamaged.
(2) Ensure that the tapers in the Barrels are clean and dry.
(3) Lubricate the external tapers of the Diaphragm with pump oil and insert the Diaphragm
into the Barrel, from the pump side.
(4) Fit the Delivery Valve assembly (43). Confirm that it is a Delivery Valve and that it is
fitted correctly.
(5) Replace Valve Nut (44) and torque it to 135 Nm.
(6) Lubricate Mandrel (52) with pump oil, and push the Mandrel as far as possible into the
Diaphragm (51).
(7) Fit Inlet Valve assembly (45 or 46). Confirm that it is an Inlet Valve and that it is fitted
correctly. Grease the outside of the Inlet Valve to ease assembly.
(8) Replace Valve Nut (41) and fully tighten. Where access is possible, use a socket and
torque wrench and torque the Valve Nut to 135 Nm.
(9) The pump will now require oil bleeding in accordance with the procedure detailed in
Section 3, Para 18.
Pump Strip and Re-Assembly
NOTES (1) The work is best carried out in a Repair Stand (Part No 042-177).
(2) Refer to Para 9 for drawing information.
(3) When ordering replacement parts, Barrel (53), Baffle (54), Seal (55) and Cylinder (57) are
supplied as an assembly. Always quote the Pump Number (see Identification Plate) and
Barrel Letter Code (see Fig 4.2) when ordering.
Flowplant P Pump Manual Issue 7
53
13. Carry out a strip of the pump, as follows:
(1) Carry out the procedure for removal of Diaphragms and Valves, as detailed in Para 11,
(2) Unscrew the Bleed Screws (21) from the Bleed Rings (48) and remove the Bleed Rings.
(3) Remove the socket-head Captive Screws (7) from the Cover Plate (10) with '0' Ring (9)
from the delivery side of the pump, then slacken Captive Screws (7) in Cover Plate (10)
on the inlet side of the pump.
(4) Slacken all Locknuts (47), half a turn only.
(5) Unscrew all socket-head Set Screws (69) that are holding down the End Plate, and screw
them into the adjacent tapped holes.
(6) Tighten these Set Screws (69) down diametrically, until the End Plate is lifted. It may be
necessary to put some freeing oil (WD 40) around the Barrels before starting to
withdraw the End Plate.
(7) Progressively add packing between Set Screws (69) and the Crankcase until the End
Plate is clear of the Barrels. Alternatively, Set Screw (Part No 023¬067) may be used
dispensing with the need for packing.
NOTE If Barrels tend to come up with the lid as Set Screws are tightened (and Locknuts (47)
are slackened), tap the Barrels down with a nylon mallet.
(8) Working on one Barrel at a time, remove the Circlip (40) from the Gudgeon Pin (39).
Remove by pushing Gudgeon Pin down.
(9) Remove Locknut (47).
(10) Disengage Piston (56) from the Con Rod (38), and remove Barrel Assembly.
NOTE Keep all components in individual Barrel Sets, ie when re-assembling use same Con Rod,
Gudgeon Pin and Cylinder.
(11) When all Barrel Assemblies have been removed, unscrew Nyloc Nut (29).
(12) Lift off the Washer (28), inner race of the Floating Bearing (32), Counter Balance (23),
Retaining Ring (37), and Con Rods (38), Eccentric (35) and Bearing (36), Counter Balance
(23) and Key (27). The Shaft (25) can now be pulled out through location Bearing (31).
Flowplant P Pump Manual Issue 7
54
(13) Remove Nyloc Nuts (17) and Washers (8), and lift off the Oil Seal Carrier (24) and
Selector Support (58).
(14) Using a small hand press and Dolly (Part No 201-007), remove Bearings (31 and 32).
14. Carry out a re-assembly of the pump, generally reversing the procedure used in Para 13, noting
the following points:
a. When replacing the Shaft, care should be taken to prevent the Shaft keyway from
damaging the Oil Seal (10).
b. Barrels are letter coded and must be fitted in their correct position (Fig 4.2). All bleed
holes in the Barrels must be in the vertical position.
VIEW ON FRONT (DELIVERY SIDE) OF PUMP
Fig 4.2 Pump Cylinder Code
c. Fit new Gudgeon Pin Circlips (40) whenever they have been removed from the Gudgeon
Pins.
d. Gudgeon Pins with one Circlip already fitted should be inserted from beneath the Con
Rods.
e. Nyloc Nut (29) must be torqued to 135 Nm.
3 CYLINDER AEJ
4 CYLINDER - ADGK
6 CYLINDER - ACEGJL
8 CYLINDER - ABDFGHKM
Flowplant P Pump Manual Issue 7
55
f. When fitting the End Plate, ensure that the Locknuts (47) are slack. Tap down the End
Plate as evenly possible, and then tighten the Locknuts (47) before tightening the Set
Screws (69).
g. Apply grease to the hose tail of the Valve Nut (41) to ease fitting of the Tee Moulding
(M3)
h. Apply grease to the outside of the Tee Moulding (M3) in the area of the Retaining Ring
(37), to ease removal and assembly of the Retaining Ring over the Tee Moulding.
Pump Running In
15. Prior to running in the pump after overhaul or major component replacement, the pump should
be filled with oil to the correct level. Refer to Lubrication Chart (Table 4.2) for details of
recommended oil types and pump oil capacities, and Section 3, Para 18 (1) for pump oil level
procedure.
16. The pump should also be bled of air in accordance with the procedures given in Section 3, Paras
18 and 19.
17. Run the pump at maximum pressure for 10 minutes, checking for leaks and monitoring the flow.
Check the results against the pump performance data. The following points should be taken into
account when determining maximum pressure to be used when running in the pump:
a. If the pump is being used on a system that has a lower working pressure than the
maximum for the pump, then running in of the pump should be at the lower pressure.
b. Check the pump Identification Plate for the maximum working pressure of the pump
before commencing the running in test. Some models of pumps have working pressures
lower than stated, in which case running in should be carried out at the lower pressure.
Flowplant P Pump Manual Issue 7
56
Fig 4.3 ‘P’ Type and High Lift Pump – Pump Assembly
48
21
10
9
22
2
11
4
5
3
6
9
10
8
7 A
14
15
16
26
27
25
17
8
30
24
31
22
47
68
67
34
15
1
23
36
50
HARBEN SYSTEMS LTD 1979
C
Drawing No.2A/2
10
A
54
55
56
57
50
1
69 B
18
17
67
58
34
20
29
28
32
23
35
40
38
B
37
39
MAINTENANCE ONLY
59
73
74
74
66
60
65
64
61
62
63
Flowplant P Pump Manual Issue 7
57
Fig 4.4 ‘P’ Type and High Lift Pump – Barrel Assembly
FOR MANIFOLD
ASSY REFER TO
FIG 4.7
H
R
Flowplant P Pump Manual Issue 7
58
Fig 4.5 ‘P’ Type and High Lift Pump – Pump Cross-Section
83
58
80 81
58
¾” BSP
(Item 76)
(Item 75)
53
46
41
3
6
4
5
¾” BSP
78
77
8
11
7 8
10
2
3
6
10
7
8
12
71
72
70
67 68
69 8
9
23
22
8
17
20
58
18
59
63
60
61
62
64
65
66
73 74
49
42
44
43
48
1
82
5
53
51
52
54
55
50
47
45
41
29
28
32
34
37
21
13
14
17
15
16
8
19
22
24
27
31
25
26
30
34
35
36
57
56
38
39
40
Flowplant P Pump Manual Issue 7
59
Fig 4.6 ‘P’ Type and High Lift Pump-Pump Parts List
Flowplant P Pump Manual Issue 7
60
Fig 4.7 ‘P’ Type and High Lift Pump- Inlet Manifold Assembly
4
7
4
6
4
6
7
4
6
7
4
6
7
4
1
5
6
5
8
2
3
7
Flowplant P Pump Manual Issue 7
61
Fig 4.8 Manifold Selector Assembly
Flowplant P Pump Manual Issue 7
62
Fig 4.9(a) Inline selector Assembly
Flowplant P Pump Manual Issue 7
63
Fig 4.9(b) Inline Selector Assembly
Flowplant P Pump Manual Issue 7
64
SECTION 5
WARRANTY
Flowplant P Pump Manual Issue 7
65
SECTION 5
WARRANTY
Page
Warranty
Warranty of New Products 66
Warranty of Spare Parts 66
Limitations of Warranty
Non Warranty Items 67-69
Service and Spares 69
Flowplant P Pump Manual Issue 7
66
WARRANTY
Warranty of New Products
Equipment manufactured and supplied by Flowplant is warranted to be free from defects in materials
and workmanship.
The warranty includes both parts and labour necessary to correct any such defects.
The warranty period for new products is 12 months from date of despatch from our factory or 2000
operating hours, whichever occurs soonest.
We shall repair or, at our option, replace free of charge any product, part(s) or component(s)
manufactured by Flowplant which fail due to faulty manufacture or material within the warranty period.
Warranty of Spare Parts
The warranty for new spare parts is 6 months from date of despatch on materials and workmanship or
250 operating hours, whichever occurs soonest.
The warranty for reconditioned spare parts is 90 days from date of despatch on materials and
workmanship.
Provided always that
a) They are returned to Flowplant for inspection (carriage paid), along with a copy of the original
part(s) sale invoice (where necessary); and
b) All terms agreed by Flowplant for payment of such goods have been complied with; and
c) If a defect/failure is discovered before the expiration of the warranty, notification must be given
to the Flowplant service department immediately
d) Any claim hereunder is made within 30 days of the date of discovery of the defect/failure.
Provision of this warranty shall not apply to any Flowplant product which has been:
a) Used for a purpose for which it is not designed for; or
b) Applied to a use which has not been approved by Flowplant; or
c) Subject to misuse, negligence, lack of maintenance or accident; or
d) Repaired or altered in any way so as, in the judgment of Flowplant, to adversely affect its
performance and reliability
Flowplant P Pump Manual Issue 7
67
Limitations of Warranty
The new product and spare parts warranty is limited to defects in material or workmanship of the
product. It does not cover loss of time, inconvenience, property damage or any consequential damages.
Repair or replacement of the product is your exclusive remedy.
Our liability under this clause shall be in lieu and to this exclusion of any warranty or conditions implied
or expressed by law as to the quality or fitness for purpose of any goods supplied hereunder PROVIDED
THAT nothing in this clause shall operate so as to exclude liability for death or personal injury arising
from the negligence of the company or its employees.
Our obligations as aforesaid shall constitute the full extent of our liability in respect of any loss or
damage sustained by the purchaser whether caused by any breach of this contract or by our negligence
or otherwise and we shall not be liable to make good or pay for loss of use of the goods, loss of revenue,
loss of profit or goodwill or any direct or consequential losses howsoever caused and the purchaser
undertakes to indemnify us against any such claims against us by third parties.
On order to comply with the provision of the Health and Safety at work etc., Act 1974 in respect of
articles manufactured, supplied or installed for use at work we test all our products before they leave
our factory and supply them with adequate instructions for their proper use. Further copies of these
instructions are available from us upon request.
Non Warranty Items
The Warranty terms are a precise statement of Flowplant Group Ltd's intention to cover the
replacement or repair cost, on a standardised and agreed basis, of any product failure resulting from
defective material or sub-standard workmanship during the manufacturing process.
The following items are considered to be of a Maintenance nature and should not be subject of a claim.
Engine (Manufacturers Warranty Applies)
Routine servicing of injector/fuel injection equipment.
Heavy fuel consumption rectified by engine adjustment.
Adjustment of fan belts/throttle and controls.
Tightening of all sump and cover bolt/nuts water connections and exterior oilpipes and filter
bolts.
Filters and the cleaning of filters.
Engine service components.
Adjustments.
Brakes (Trailer)
Brake shoe adjustment/bleeding and topping up of reservoir/draining of air systems where not
due to a defective part.
Brake squeal from brake linings.
Replacement of linings due to fair wear and tear.
Tightness of air lines/pipes.
Filters and the cleaning of filters.
Brake fluid.
Flowplant P Pump Manual Issue 7
68
Electrical (all products) Manufacturers Warranty Applies
Cleaning of terminals.
General maintenance of batteries, dynamo/alternator, starter etc.
Adjustment to ignition system components.
General adjustment to electrical control current settings.
Brushes and other items due to fair wear and tear.
Contactor tips and springs.
Replacement of lamps, lenses and bulbs.
Steering/Running Gear
Front wheel alignment, track adjustment.
Steering adjustment.
Hub bearing and float adjustment.
Jockey wheels.
Hydraulics ( all products)
Tightening of hydraulic fittings and couplings.
Filters and the cleaning of filters.
Hydraulic fluid.
Chassis (self-propelled and trailer-mounted units)
General rattles.
Paint chips.
Alignment and adjustment of panels etc.
Deterioration of paint and external fittings due to neglect, exposure and fair
wear and tear.
Accidental damage.
Lubrication (all products)
Complete or partial lubrication services.
Corrosion (all product)
Damage caused by adverse weather/atmosphere conditions.
General (all products)
Fair wear and tear.
Any work carried out to improve the general finish of the machine above
what is known to be the factory standard.
Failure to maintain the equipment in accordance with the manufacturer's recommendations.
REMEMBER:
i. The replacement or repair of tyres is not covered by the Company's warranty terms.
ii. In the case of van and truck mounted equipment the warranty relating to the actual vehicle
remains the responsibility of the vehicle manufacturer or supplier.
In order to comply with the provisions of the Health and Safety at Work Act 1974 in respect of articles
manufactured, supplied or installed for use at work, we test all our products before they leave our
Flowplant P Pump Manual Issue 7
69
factory and supply with them adequate instructions for their proper use. Further copies of these
instructions are available from us on request.
We shall not be liable for loss, injury or damage of whatever nature caused by goods, design, technical
information, suggestions, etc supplied by us where as the case maybe they have been structurally
modified or misused or misapplied or have not been properly cared for and maintained, and the
purchaser hereby agrees to indemnify us against all such claims and demands or by whomsoever they
are brought.
Service and Spares
Flowplant provide service and spares cover in most parts of the world. When ordering spares, please
quote:-
a) Your company name and address.
b) Destination of parts, if different from above.
c) Description and part number.
d) Quantity required.
e) Price and method of payment.
f) Delivery date.
g) Order number.
h) Confirmation of order
When requesting service or repairs, please state:-
a) Your company name and address.
b) Location of machine/unit if different from above.
c) Type and model of machine/unit.
d) Pump serial number.
e) Problem(s) with machine/unit.
f) Availability of machine/unit for service or repairs.
g) Date of service and site contract.
h) Cost and method of payment.
i) Order number.
j) Confirmation of order.