TOTAL HARDNESS KIT
Code 4482-DR-LI-01 | Direct Reading Titrator, 0-200 ppm
QUANTITY CONTENTS CODE
15 mL *Hardness Reagent #5 *4483-E
*Reagent is a potential health
hazard. READ SDS: lamotte.com
Emergency information:
Chem-Tel USA 1-800-255-3924
Int’l, call collect, 813-248-0585
15 mL *Hardness Reagent #6 Solution *4485-E
60mL Hardness Reagent #7 4487DR-H
1 Test Tube, 5-10-12.9-15-20-25 mL,
glass, w/cap
0608
1 Direct Reading Titrator, 0-200 Range 0382
1 Pipet, 0.5 mL, plastic 0353
To order individual reagents or test kit components, use the
specified code number.
NOTE: Read the Direct Reading Titrator Instruction Manual before proceeding. The Titrator
is calibrated in terms of total hardness expressed as parts per million (ppm) calcium
carbonate (CaCO
3
). Each minor division on the Titrator scale equals 4 ppm CaCO
3
.
PROCEDURE
1. Fill the test tube (0608) to 12.9 mL line with sample water.
2. Add five drops of *Hardness Reagent #5 (4483). Swirl to mix.
3. Add five of Hardness Reagent #6 Solution (4485) and swirl to mix. Solution will turn red
if hardness is present. If solution is blue, there is no measurable amount of hardness.
4. Fill the Direct Reading Titrator (0382) with Hardness Reagent #7 (4487DR). Insert
Titrator in the center hole of the test tube cap.
5. While gently swirling the titration tube, slowly press the plunger to titrate the sample
until the red color changes to blue. Read the test result directly from the scale where
the large ring on the Titrator meets the Titrator barrel. The result is expressed as Total
Hardness in ppm CaCO
3
.
EXAMPLE: Plunger tip is 3 minor divisions below line 80. Test result is 80 plus
(3 divisions x 4) equals 92 ppm.6.
6. If the plunger tip reaches the bottom line on the Titrator scale (200 ppm) before the
color change occurs, refill the Titrator and continue the titration. When recording the
test result, be sure to include the value of the original amount of reagent dispensed (200
ppm).
7. To convert ppm Hardness to grains per gallon (gpg), multiply by 0.058. Record as gpg
Hardness as CaCO
3
.
gpg CaC0
3
= ppm CaC0
3
x 0.058
LAMOTTE COMPANY | 802 Washington Avenue | Chestertown, Maryland | 21620 USA
800.344.3100 | +1 410.778.3100 (Outside USA) | Fax 410.778.6394 | lamotte.com
©2023 LaMotte Company, All Rights Reserved 64482-DR-LI-01 12.21.2023
ANALYSIS OF HARNESS IN SALT WATER
When sea and estuarine waters containing very high levels of mineral salts are tested,
the sample must be diluted before titration. This test kit contains a calibrated pipet for
performing the dilution described below.
1. Use the 0.5 mL pipet (0353) to transfer 0.5 mL of the salt water sample to the test tube
(0608).
2. Dilute to the 12.9 mL line with distilled water (a 1 to 25.8 dilution).
3. Follow Steps 2 through 6 above. Multiply the Titrator reading by 25.8. Record as ppm
Total Hardness as CaCO
3
.